Quantcast
Channel: Main Sequence Software - Latest posts
Viewing all articles
Browse latest Browse all 52138

Manual Focusing, HFR star button, large sensor, not accurate

$
0
0

Hello SGP Team and Ken welcome back! I just wanted to bring up some issues I've experienced since the new HFR changes. I have seen inaccurate HFR representations. I am not sure if this is a result of resizing the image to help speed up the HFR calcuation with wide sensors on slower computers.

Here is a comparison of some data where the focus is gradually declining then corrected.

According to SGP it appears the focus is fine statistically, however when comparing in another program the FHWM is declining. When I am out in the field it appears to me that everything is fine because the HFR number was declining or around the same level, however in reality it is actually getting worse.

It's also quite difficult to see if you are out of focus sometimes with the bayered matrix (in my opinion). Especially on tablets out in the field, on a 24" monitor a little easier.

I have shared frames 1->9 if you find this helpful:

https://drive.google.com/drive/folders/0BxRPkA5ux2wlM2Rua1Uyajd6ZlE?usp=sharing

Thank you again for your excellent program and any time have on this issue.


Viewing all articles
Browse latest Browse all 52138

Trending Articles