Greetings
After my upgrade to 2.5.2.5 pyxis rotator does not seem to work. I am running pyxis commander 3.02
Downgrading to 2.5.2.4 works fine
My thoughts
The behavior may be related to
"SGPro now attempts to detect external device disconnections (and provide a notification to fix it)"
When starting SGPpro and connecting the rotator, if the rotator is not ready usually I need to home it.
So the steps are connect equipment/rotator -> settings -> home rotator -> ready to go
I think that the rotator once it performs its function it disconnects.
In 2.5.2.5 I connect equipment/rotator. Home and the rotator disconnects
Form the logs
[10/20/2016 10:04:11 PM] [DEBUG] [Equipment Connectivity Thread] SGPro thinks the rotator is connected, but it's not, syncing UI...
[10/20/2016 10:04:11 PM] [DEBUG] [Equipment Connectivity Thread] Adding sequence level notification: External disconnect of rotator detected...
[10/20/2016 10:04:11 PM] [DEBUG] [Equipment Connectivity Thread] Handling monitoring event (Email 1, Warning): External disconnect of rotator detected...
[10/20/2016 10:04:11 PM] [DEBUG] [Main Thread] Disconnecting ASCOM Rotator: ASCOM.PyxisUniversal.Rotator
I have uploaded both logs. They are not that clean but I can reproduce the issue easily if needed.
Good rotator is on 2.5.2.4
Bad rotator is on 2.5.2.5
Please advise
bad rotator.txt (47.2 KB)
good rotator.txt (539.9 KB)